Pedestal loads
Back to main menu



Pedestal loads

The maximum safe radial load for a pedestal casting is based on the bearing static rating Cor. The full Cor rating can be applied if the angle of the load falls within the shaded area of the sketch.

If the load falls outside the shaded area or is greater than Cor, please consult our technical department.

When considering suitability of pedestal castings, the resultant effective radial load must be used. The effective radial load is the resultant of net loads and appropriate dynamic factors, excluding speed and life factors.

If the axial load exceeds 50% of the axial rating (Ca), please consult our technical department.

For shock and pulsating loads, steel or ductile iron pedestals should be considered. For loads within 45° of the horizontal, the base should be chocked or dowelled, these modifications can be made upon request.


Flange load

The maximum load on cast iron flanges is 0.26 Cor or 0.25 Ca. Higher loads and shock conditions require ductile iron or steel flanges and high tensile bolts.



Back to main menu 

 
















Cooper Service Centers
USA and Mexico
The Cooper Split Roller Bearing Corp
5365 Robin Hood Road, Suite B
Norfolk, VA 23513
USA
Telephone 757 460 0925
Fax 757 464 3067
UK, Asia, Australasia and Middle East
Cooper Roller Bearings Co Ltd
Wisbech Road
King's Lynn
Norfolk PE30 5JX
England
Telephone +44 (0) 1553 763 447
Fax +44 (0) 1553 761 113
Europe and South America
Cooper Geteilte Rollenlager GmbH
Postfach 100 423
Oberbenrader Str 407
47704 Krefeld
Germany
Telephone +(49) 2151 713 016
Fax +(49) 2151 713 010
China
Cooper Beijing Office
Room 909, Canway Building tower 1,
No 66, Nanlishi Road,
Xicheng District, Beijing
Postcode:100045
Telephone 86-10-68080805 68080803
Fax 86-10-68080801
www.CooperBearings.com