Pedestal
loads
The maximum
safe radial load for a pedestal casting is based on the bearing
static rating Cor. The full Cor rating can
be applied if the angle of the load falls within the shaded area
of the sketch.
If the load
falls outside the shaded area or is greater than Cor,
please consult our technical department.
When considering
suitability of pedestal castings, the resultant effective radial
load must be used. The effective radial load is the resultant of
net loads and appropriate dynamic factors, excluding speed and life
factors.
If the axial
load exceeds 50% of the axial rating (Ca), please consult
our technical department.
For shock and
pulsating loads, steel or ductile iron pedestals should be considered.
For loads within 45° of the horizontal, the base should be chocked
or dowelled, these modifications can be made upon request.
Flange load
The maximum
load on cast iron flanges is 0.26 Cor or 0.25 Ca.
Higher loads and shock conditions require ductile iron or steel
flanges and high tensile bolts.
|