Selection
of base oil viscosity grade (ISO-VG)
To determine
the proper viscosity grade, the Cooper part number, operating temperature
and speed (rpm) must be known.
Select the appropriate
bearing geometry factor from the table below for the given shaft
size and Series.
Multiply the
geometry factor by the bearing rpm to obtain the velocity factor.
Starting with the VG 150 graph on the next page (Temperature
range charts), draw a vertical line from the calculated velocity
factor and a horizontal line from the bearing operating temperature.
If the lines
intersect inside the shaded area, a grease or oil containing a base
oil viscosity grade (ISO-VG) of 150 should be suitable for use.
If the intersection
of the lines is outside the shaded area on the VG 150 graph, follow
the same procedures as above to determine if a VG 220 or VG 460
would be suitable.
For conditions
not covered by the chart and graphs, please contact our technical
department.
|