Installation guide

pg 1 | pg 2 | pg 3 | pg 4 | pg 5
Back to main menu



Selection of lubricants

You must know the operating temperature and speed (RPM) of the Cooper bearing being evaluated. Select the appropriate bearing goemetry factor from the table provided. Multiply the geometry factor by the shaft RPM to obtain the velocity factor. On the graph below, draw a vertical line up from the calculated velocity factor and a horizontal line from the bearing operating temperature. If the lines meet in the shaded area, the listed viscosity grade is suitable. Please consult our engineering department with any questions.

 
Cooper Bearing recommended speed and temperature range for ISO VG 150 grease and oils
 
Cooper Bearing recommended speed and temperature range for ISO VG 220 grease and oils
 
Cooper Bearing recommended speed and temperature range for ISO VG 460 grease and oils